analytica - April 17-20,2012 | New Munich Trade Fair Centre | Munich | 23rd International Trade Fair for Laboratory Technology, Analysis, Biotechnology and analytica Conference
Exhibitor Database
analytica.de
analytica
analytica.de analytica.de analytica.de Dates & Facts
analytica.de
analytica.de analytica.de analytica.de Reasons for your participation
analytica.de
analytica.de analytica.de analytica.de Exhibiton fields
analytica.de
analytica.de analytica.de analytica.de Prices and Application
analytica.de
analytica.de analytica.de analytica.de Hall assignments
analytica.de
analytica.de analytica.de analytica.de Exhibitor Center
analytica.de
analytica.de analytica.de analytica.de Exhibitor service
analytica.de
analytica.de analytica.de analytica.de Conference program/Events
analytica.de
analytica.de analytica.de analytica.de analytica-world
analytica.de
analytica.de analytica.de analytica.de Review 2010
analytica.de
analytica
Home  Exhibitor  Exhibitor service  Technical infrastructure
Halls
analytica.de
analytica.de
analytica.de analytica.de analytica.de
analytica.de analytica.de
analytica.de analytica.de
 
Fairgrounds map
analytica.de

  • Fairgrounds map as PDF file for downloading
Technical specifications
analytica.de
Partial air-conditioning in the halls and enclosed entrances ensure that all facilities are both functional and comfortable regardless of the season or weather. Exhibitors throughout the grounds are supplied with electricity, water and compressed air through a functional system of floor/ground conduits. The most modern information technology for transmitting data, voice and images as well as WLAN technology are standard in all halls. Naturally, innovative communications technology ensures optimum, high-speed connections between market partners at all times. 
Description of halls and outdoor exhibition site
analytica.de
Halls A1-A6
B1-B5
B6
(high hall)
C1-C3
C4 B0
(ICM)
Length 161 m 161 m 143 m 139 m 65 m
Width 71 m 71 m 71 m 71 m 54 m
Total exhibition area approx.
11,000 m²
approx. 11,000 m² approx. 10,000 m² approx. 10,000 m² approx. 3,500 m²
Clearance height of longitudinal walls
(along edge of hall between entrances)
approx.
5.70 m
approx.
7.80 m
approx.
5.70 m
approx.
5.70 m
approx.
4.00 m
(edge of hall)
Clearance height of hall grider supports
(along sides of hall)
approx.
10.75 m
approx.
15.25 m
approx.
10.75 m
approx.
10.75 m
-------
Clearance height of beam ties
(hall center)
approx.
11.5 m
approx.
16 m
approx.
11.5 m
approx.
11.5 m
approx.
4.20 m
(hall center)
Hall floor covering Mastic asphalt Mastic asphalt Mastic  asphalt Mastic  asphalt Parquet
Permissible floor load   5 t/m²     (50 kN/m²)   5 t/m²   (50 kN/m²)     5 t/m²     (50 kN/m²)

   5 t/m²    (50 kN/m²)

  2 t/m²  (20 kN/m²)
Permissible point load
(0.3 x 0.3 m)
(does not apply to utility duct covers)
10t
(100 kN)
10t
(100 kN)
10t
(100 kN)
10t
(100 kN)
8t
(80 kN)
Permissible vertical load per suspension point 100 kg
(1KN)
100 kg
(1KN)
100 kg
(1KN)
100 kg
(1KN)
100 kg
(1KN)
Entrance gates:
Vehicle access:
(size) and [number]
(4.5 x 4.5m)
[6]
(4.5 x4.5m)
[8]
(4.5 x 4.5m)
[6]
(4.5 x 4.5m)
[8]
-------
No vehicle access
(size) and [number]
(2.5 x 4.5m)
[6]
(2.5 x 4.5m)
[2]
(2.5 x 4.5m)
[4]
(2.5 x 4.5m)
[2]
(12.5x 4 m)
[1]
Artificial illumination 100 Lux/m² 100 Lux/m² 100 Lux/m² 100 Lux/m² 400 Lux/m²
Ventilation Partially air-conditioned Partially air-conditioned Partially air-conditioned Partially air-conditioned Partially air-conditioned
Utilities supplied via ducts that cross halls at right angle to longitudinal walls. Distance between duct centers: 5 m 5 m 4.5 m (*) 4.5 m 4.85 m
Width of utility ducts 0.35 m 0.35 m 0.35 m 0.35 m 0.35 m
Width of duct covers 0.43 m 0.43 m 0.43 m 0.43 m 0.43 m
Utility connections
Water diam. 25 / min. 3.5 bar diam. 25 / min. 3.5 bar diam. 25 / min. 3.5 bar diam. 25 / min. 3.5 bar diam. 25 / min. 3.5 bar
Waste water diam. 100 diam. 100 diam. 100 diam. 100 diam. 100
Sprinklers diam. 50 diam. 50 diam. 50 diam.50 diam. 50
Compressed air diam. 50 / min. 10 bar diam. 50 / min. 10 bar diam. 50 / min. 10 bar diam. 50 / min. 10 bar diam. 50 / min. 10 bar
Gas diam. 25 / 20 mbar diam. 25 / 20 mbar diam. 25 /  20 mbar diam. 25 /  20 mbar diam. 25 / 20 mbar
Electricity 200 W/m² 200 W/m² 200 W/m² 200 W/m² 200 W/m²
Telecommunications
User-independent wireline connections (telephone, fax, ISDN, LAN) 300 300 300 300 100 
Wireless telephone connections (DECT) approx. 100 approx. 100 approx. 100 approx. 100 approx. 50
Broadband connections (TV, satellite) 150 150 150 150  56
Fiber-optic connections (single-mode and/or gradient fiber) 150 150 150 150  56

(*) Hall C1 also has two utility ducts that run parallel to the longitudinal walls.


Outdoor exhibition site  
Width of access roads 8 m / 12 m
Road surface Asphalt
Surface of exhibition area Seeded gravel bed (grassed-over gravel-humus mixture, stony in parts)
Max. permissible load 50t/m² (500kN/m²)
Illumination 30 Lux/m²
Utilities
- Water supply diam. 40 / 3.5 bar
- Waste water/ sewage DN100
Electricity 50 W/m²
Telecommunications
- User-independent wireline connections (telephone, fax, ISDN, LAN) 1400
- Wireless telephone connections (DECT) approx. 200
Broadband connections (TV, satellite) 100
Fiber-optic connections (single mode and/or gradient fiber) approx. 100


Separate technical guidelines apply to the foyer of the ICM.
Floors – Permissible loads – Gates

General:
With the exception of Hall B0, motor vehicles can be driven into the halls. However, doing so is only permissible at walking pace. The underfloor utility ducts can withstand the weight of a vehicle when covered. With an evenly distributed load, their load-bearing capacity corresponds to that of the general load-bearing capacity of the floor in question. The maximum point loads posted for the hall floors does not apply to the areas near the utility ducts.

The weight limits posted for the passenger and freight elevators may not be exceeded under any circumstances. Passenger elevators and escalators may not be used to transport freight.

Any damage caused by non-compliance with these guidelines must be remedied by MMG at the expense of the exhibitor and/or his agents.


  • A description of the halls and the outdoor exhibition area can be download here: PDF file
analytica.de
Print Print      Send page via E-mail Send page via E-mail
top Top
analytica.de
analytica - YouTube analytica - Flickr
analytica
Services
Contact Contact
MMI  contacts abroad MMI contacts abroad
Information request Information request
Opening hours Opening hours
Getting There Getting There
Your stay in Munich Your stay in Munich
Visa Service Visa Service
Visa invitation letter Visa invitation letter
Media Kit 2012 Media Kit 2012
Partners Partners
Sponsors analytica 2012 Sponsors analytica 2012
Sponsors Live Lab Sponsors Live Lab
analytica.de
Newsletter
Subscribe to the Newsletter now!
 analytica more
analytica
my.analytica.de
Username
Password
Password forgotten?
Register now!
i All about my.analytica.de

The global network of analytica trade fairs
  analytica China  
  analytica Vietnam  
  analytica Anacon  
  analytica-world.com  
analytica
ad




Medizinbedarf, Therapiebedarf, Laborbedarf bei Mercateo online kaufen
© Messe München GmbH, All rights reserved | Imprint | Data protection | Sitemap | Recommend this page | Refer a Business Partner Messe München International